1. Physical properties
- Particle size uniformity: deviation must be less than 5% (such as ISO 3310-1 standard) to avoid short-flow phenomenon;
- Mechanical strength: wear rate should be less than 1% (refer to GB/T 17431-2010) to prevent breakage during operation;
- Density adaptation: the density of filter media in water treatment must be greater than 1.0g/cm³ to ensure sedimentation.
2. Chemical stability
- Acid and alkali resistance (pH tolerance range 2-12), antioxidant (such as activated carbon iodine value ≥800mg/g);
- No dissolution (such as heavy metal content must comply with GB 5749-2022 drinking water standard).
3. Economic and sustainable
- Service life ≥5 years (taking quartz sand as an example);
- Regeneration cycle (such as activated carbon thermal regeneration temperature needs to reach 600-800℃).